How to read a heating oil tank – pump first, then read the black pointer
Pneumatic tank gauges have two pointers. The black one is the measurement; the red one just marks the last reading. And: enter the value exactly as the gauge shows it – in percent or liters.
In short
On pneumatic tank gauges, pump first, then read the black pointer – the red one is only a marker. Enter the value in the unit of the scale. Example: the gauge shows 45 % – you enter 45 %. For ordering oil: 45 % of a 6000 l tank is about 2700 l.
See also: Year-end reading on Dec 31
Which pointer shows the fill level?
Tap a number in the drawing to highlight its explanation.
How to read a heating oil tank in four steps
Check the scale
Does the scale show % or liters? Enter the value in exactly that unit and don't convert it.
Pump
Operate the hand pump several times until the black pointer stops rising.
Read the black pointer
Read the black pointer immediately. Ignore the red pointer.
Reset the red pointer
Turn the red marker pointer to the new level. That way the next person sees at a glance how much has been used since.
Common mistakes with heating oil tanks
Entering a converted value
If the gauge shows 50 %, enter 50 % – not 3000 liters. Converting is useful for ordering, but it does not belong in the reading. A value above 100 % points to a reading error or a faulty gauge.
Reading the red pointer
The red pointer shows an old level. Read it and you'll report the same value over and over.
Reading without pumping
The black pointer slowly drops after the last measurement. Without pumping, it shows too little.
Questions about reading heating oil tanks
What does the red pointer on the tank gauge mean?
On pneumatic tank gauges such as the AFRISO Unitop, the red pointer is a manually adjustable marker for tracking consumption. Read the fill level from the black pointer.
How do I read a heating oil tank with a dipstick?
Insert the clean dipstick vertically down to the bottom, pull it out and read the height of the oil mark in cm. You can only convert this to liters using the gauging table for that specific tank.
How do I convert the fill level to liters?
If the scale shows percent by volume, multiply the percentage by the tank capacity on the rating plate: 45 % of 6000 l is about 2700 l. If it shows the fill height – or you measure with a dipstick – you need the tank manufacturer's dipstick chart, because depending on the tank shape, one centimeter corresponds to a different number of liters. In the reading, you still enter the value the gauge shows.